Rekord LOINC: 24342-8

Dostępne tłumaczenie polskie ACTIVE

Powrót do listy LOINC
Tłumaczenie polskie
Komponent
Właściwość
Aspekt czasowy
System
Typ skali
Klasa
Krótka nazwa
Długa nazwa wspólna
Definicja i opis
Szczegóły rekordu LOINC
Informacje podstawowe
Kod LOINC: 24342-8 FHIR
Long Common Name: Gas and Carbon monoxide panel - Capillary blood
Short Name: Gas + CO Pnl BldC
Status: ACTIVE
Class Type: 1
Fully Specified Name (FSN)
PL Tłumaczenie polskie
Panel gazów i tlenku węgla : - : punkt w czasie : krew włośniczkowa : ilościowy : -
EN Oryginalna wersja angielska
Gas & CO panel : - : Pt : BldC : Qn : -
Klasyfikacja
Class:
PLpanele badań biochemicznych
ENPANEL.CHEM
Consumer Name: -
Order/Observation: Order
Panel Type: Panel
Informacje dodatkowe
Units Required: Y
Example Units: -
UCUM Units: -
Version Last Changed: 2.42
Definicja i opis

Knowing the concentration of inspired O2 is important to the interpretation of PO2 results. Inspired O2 can be recorded in two ways- as percent- of O2 delivered to the patient (Venturi mask, re-breather mask, or ventilator) or as liters of oxygen per minute (nasal canula). This panel includes terms for recording the inspired O2 in either fashion. But because only one will apply and labs do not always receive this information they are designated as optional. The term "oxygen saturation" is often used to refer to two distinctly different quantities, hemoglobin oxygen saturation (recommended symbol = sO2) and fractional oxyhemoglobin (recommended symbol = FO2Hb). The former is sometimes called functional oxygen saturation and the later, fractional oxygen saturation Hemoglobin oxygen saturation = is the amount of oxyhemoglobin expressed as the percent of the hemoglobin able to bind oxygen, i.e. oxyhemoglobin (O2Hb) + deoxyhemoglobin (HHb). sO2 = 100 x O2Hb/ (O2Hb + HHb) Fractional oxyhemoglobin = the amount of oxyhemoglobin expressed as a percent of the total hemoglobin, where tHb = O2Hb + HHb + [COHb + MetHb + SulfHb]. Note that COHb, MetHb, and SulfHb, cannot carry oxygen and are thus called dyshemoglobins. FO2Hb = O2Hb/tHb Gas machines that can measure carbon monoxide, could, in principle, also report FO2Hb, and we had assumed that they would. However, at least some machines that do measure COHb and MetHb provide no option for reporting FO2Hb, and report only sO2. When mapping blood gas panels that report COHb% and also report FO2Hb, map that term to the LOINC term with the component of "Oxyhemoglobin /Total hemoglobin". If such an instrument reports only "oxygen saturation, verify with the lab that they are really reporting a functional O2 sat and not the Fractional Oxyhemoglobin, because the two are not always correctly labeled. If it is sO2 then map it to the LOINC term with a component of "Oxygen saturation". When you are mapping data from a simpler Blood gas instrument (one that can read fewer than 4 wave lengths), then the O2 saturation will likely be a sO2. So map also moat that variable to the LOINC with a component of "Oxygen Saturation". (Source: McD derived from Gill and McD- 2009 09)

Powiązane nazwy

Blood - capillary; Cap bld; Cap blood; Capillary bld; Capillary blood; Chemistry; cooximetry; co-oximetry; co-oximetry panel; Finger stick; Gas + CO Pnl; Gases; Lung; Pan; PANEL.CHEMISTRY; Panl; Pnl; Point in time; Pulmonary; Pulmonology; QNT; Quan; Quant; Quantitative; Random; Respiratory

Struktura panelu
Ładowanie...

Ładowanie struktury panelu...